Secret Sauce One of the best features of the Tekmar 356 Mixing Control unit is that it regulates mixing pumps in hydronic systems.This ability to fine tune the temperature at which a hydronic system runs allows a property owner to fine tune the comfort of their space. The Tekmar mixing control unit achieves its superior control over mixing pumps through an outdoor temperature reset sensor. In layman's terms, outdoor reset systems monitor weather conditions both in and outside of the home.So when outdoor temperatures are more frigid, the tekmar 356 can direct the mixing pump to raise the temperature of the hydronic fluid piped to a home's radiators. This provides more heat to the home.By the same token, when outdoor temperatures are warmer, the 356 can direct the mixing pump to run cool in order to maximize energy efficiency. This variable operation of the mixing pump in regards to outdoor temperature can boost a boiler's overall efficiency to levels unheralded without such control.

Image

Like the 257, the Tekmar 356 is designed for simple use. A large screen and three simple to use buttons allow a homeowner or property owner to get maximum performance from their boiler without a PhD in hydronics. Once installed, the unit quickly sets up for simple use.Even the most basic controls on the 356 allow a homeowner to tailor a boiler to their personal tastes. For intricate cases, the Tekmar 356's advanced controls provide all the finesse necessary. If these controls weren't already enough, the 356 also features a smart diagnostic routine which checks to ensure proper operation of each component in the system.The ability to modulate boiler temperature with precision makes the 356 perfect for a wide range of heating applications including radiant systems and commercial baseboard heating.

The Tekmar 257 features two stage control. This means the 257 can operate the attached boiler in either a "low" or "high" gear.

Image

You can try to rebuild it, but it is not worth my time to do it, since it could cost the customer more to take it apart and redo it, plus the parts, than it would for me to purchase a new valve and install it.

For those who live in the "rust belt", Tekmar offers the 664 snow detector/melting control unit equipped with temperature and moisture sensors that can operate snow melt equipment beneath two outdoor slab surfaces.When temperature drops below freezing with moisture in the air, the 664 then kicks on attached snow melt technologies. This Tekmar melting control goes beyond simple on/off operation, though. The 664 truly is a snow melting control, able to direct two boilers into separate snow melting zones, each with differing temperatures.Take, for example, the owner of an office building. In winter, snow melt is needed in both the blacktop parking lot as well as the building's front steps. Installing a Tekmar 664 would allow the owner of this building to set different heat settings beneath these surfaces: a lower temperature beneath the heat-friendly blacktop and a higher temperature for the cold, concrete front steps.The 664 can also place priority of one zone above the other. So if the business owner wants the parking lot cleared before the steps, the 664 can direct heat to ensure that is exactly what happens. The 664 can also control a variable speed mixing pump to make sure the hydronic fluid running throughout the snow melt system runs neither too hot nor too cold.

Image

Mineral deposits usually found in municipal water supplies crust up the insides of these valves so bad that a rebuild is frequently unsuccessful.

Getting the most out your hydronic heating system can be difficult. Luckily, Tekmar has a device that can increase efficiency and streamline the system's operations effortlessly.How's this possible you ask? The Tekmar 257 for instance, is a boiler control system - a maestro if you will, that ensures optimal performance by operating multiple boilers in symphony, conducting the flow of water to ensure a harmonious distribution of heat. Here, we will examine the benefits of each Tekmar 257, 356, and 664 hydronic heating controllers.

The thermostat communicates with the 257, and if temperatures in a room drop below the set point too quickly or for too prolonged a time, the 257 can shift into high gear. This two stage operation allows the system to provide more even heat with a quicker heat-up time.The Tekmar 257 two stage control also lessens the cold pockets often found within rooms. And just as each coin has two sides, if the system should require less heat—say in the warmer fall months—the Tekmar 257 can keep operation in the low stage to conserve energy.

I bought 10 of the Watts N35 and 3 of them did exactly like you described. I went back to the Watts 25 AUB and never have a problem. They cost a bit more however. - - - - - - - - - - - - - - - - - - - - Since 1995 (3 years before Google started) PlumbingSupply.com has been THE best plumbing supplier on the web. Please visit our sponsor [www.PlumbingSupply.com]

Does the prv have a built in union? What kind of pipe is it copper, plastic or steel? If copper, you can cut the downstream side and back out the male adapters. Then sweat a coupling or use a compression union. Peace out, Kordts

Welcome to Plbg.com (also known as PlumbingForum.com) where plumbing advice, education, information, help and suggestions are provided by some of the most experienced plumbers and plumbing contractors anywhere who all wish to "give back" to society. Since 1996 we have been free without popup or other invasive ads and known to be the best online STRICTLY PLUMBING advice site. If you have questions about plumbing, toilets, sinks, faucets, drains, sewers, water filters, venting, water heating, showers, pumps, and other strictly PLUMBING related issues then you've come to the right place. Please refrain from asking or discussing legal questions, or pricing, or where to find and/or purchase products, or any business issues, or for contractor referrals, or any other questions or issues not specifically related to plumbing. Keep all posts positive and absolutely no advertising. Our site is completely free, without ads or pop-ups and we don't track you. We absolutely do not sell your personal information. We are made possible by:

I have a Watts pressure reducer model N35B 25 to 75 lb range. I can purchase a rebuild kit $20 or buy a new one $60. The Rebuild seems easier since I assume I just replace the internal parts. Is it just as simple as removing the top and placing new parts in. New one would require more plumbing Knowlege since it screws on from both sides. The problem is the pressure creeps up after the water flow is stopped. I am at 100 psi in an hour.Use a little water and it is back to 50 lbs and it creaps up again slowly. Post Edited

Boiler Rotation The Tekmar 257 also boasts equal runtime rotation technology. As the 257 is often used to control groups of boilers, this runtime rotation measures the amount of time each boiler in the system has run.If one boiler operates more than the other, the Tekmar 257 will power down the overused boiler and instead draw heat from the under-used boiler. This way both boilers in the system are likely to last longer and provide more efficient heat.Ease of Use The Tekmar 257 features a no-nonsense interface with an easy-to-read LCD screen and large buttons. The 257 is ideal for controlling hotel or apartment building boiler systems. The 257 can also tailor performance to combi systems which provide both heat and domestic hot water to ensure an ample supply of both.

Getting the most out your hydronic heating system can be difficult. Luckily, Tekmar has a device that can increase efficiency and streamline the system's operations effortlessly.How's this possible you ask? The Tekmar 257 for instance, is a boiler control system - a maestro if you will, that ensures optimal performance by operating multiple boilers in symphony, conducting the flow of water to ensure a harmonious distribution of heat. Here, we will examine the benefits of each Tekmar 257, 356, and 664 hydronic heating controllers. Tekmar 257 The Tekmar 257 features two stage control. This means the 257 can operate the attached boiler in either a "low" or "high" gear. The thermostat communicates with the 257, and if temperatures in a room drop below the set point too quickly or for too prolonged a time, the 257 can shift into high gear. This two stage operation allows the system to provide more even heat with a quicker heat-up time.The Tekmar 257 two stage control also lessens the cold pockets often found within rooms. And just as each coin has two sides, if the system should require less heat—say in the warmer fall months—the Tekmar 257 can keep operation in the low stage to conserve energy. Boiler Rotation The Tekmar 257 also boasts equal runtime rotation technology. As the 257 is often used to control groups of boilers, this runtime rotation measures the amount of time each boiler in the system has run.If one boiler operates more than the other, the Tekmar 257 will power down the overused boiler and instead draw heat from the under-used boiler. This way both boilers in the system are likely to last longer and provide more efficient heat.Ease of Use The Tekmar 257 features a no-nonsense interface with an easy-to-read LCD screen and large buttons. The 257 is ideal for controlling hotel or apartment building boiler systems. The 257 can also tailor performance to combi systems which provide both heat and domestic hot water to ensure an ample supply of both. Tekmar 356 Secret Sauce One of the best features of the Tekmar 356 Mixing Control unit is that it regulates mixing pumps in hydronic systems.This ability to fine tune the temperature at which a hydronic system runs allows a property owner to fine tune the comfort of their space. The Tekmar mixing control unit achieves its superior control over mixing pumps through an outdoor temperature reset sensor. In layman's terms, outdoor reset systems monitor weather conditions both in and outside of the home.So when outdoor temperatures are more frigid, the tekmar 356 can direct the mixing pump to raise the temperature of the hydronic fluid piped to a home's radiators. This provides more heat to the home.By the same token, when outdoor temperatures are warmer, the 356 can direct the mixing pump to run cool in order to maximize energy efficiency. This variable operation of the mixing pump in regards to outdoor temperature can boost a boiler's overall efficiency to levels unheralded without such control. Built for the Average User Like the 257, the Tekmar 356 is designed for simple use. A large screen and three simple to use buttons allow a homeowner or property owner to get maximum performance from their boiler without a PhD in hydronics. Once installed, the unit quickly sets up for simple use.Even the most basic controls on the 356 allow a homeowner to tailor a boiler to their personal tastes. For intricate cases, the Tekmar 356's advanced controls provide all the finesse necessary. If these controls weren't already enough, the 356 also features a smart diagnostic routine which checks to ensure proper operation of each component in the system.The ability to modulate boiler temperature with precision makes the 356 perfect for a wide range of heating applications including radiant systems and commercial baseboard heating. Tekmar 664 For those who live in the "rust belt", Tekmar offers the 664 snow detector/melting control unit equipped with temperature and moisture sensors that can operate snow melt equipment beneath two outdoor slab surfaces.When temperature drops below freezing with moisture in the air, the 664 then kicks on attached snow melt technologies. This Tekmar melting control goes beyond simple on/off operation, though. The 664 truly is a snow melting control, able to direct two boilers into separate snow melting zones, each with differing temperatures.Take, for example, the owner of an office building. In winter, snow melt is needed in both the blacktop parking lot as well as the building's front steps. Installing a Tekmar 664 would allow the owner of this building to set different heat settings beneath these surfaces: a lower temperature beneath the heat-friendly blacktop and a higher temperature for the cold, concrete front steps.The 664 can also place priority of one zone above the other. So if the business owner wants the parking lot cleared before the steps, the 664 can direct heat to ensure that is exactly what happens. The 664 can also control a variable speed mixing pump to make sure the hydronic fluid running throughout the snow melt system runs neither too hot nor too cold. NEXT: View All Tekmar Controls

I have a watts N35B that is 24 years old. I would get 120 PSI in the house and my flow rate at the hose bib was 5 gpm. the pressure would not change when I screwed it in or out. I took it apart. Tons of crap inside. I rebuilt it, cleaning everything, replacing the dried out o rings and washer with ones that I had on hand. The Diaphram was still usable so I reused it. ( I can order one and replace that later ) Put everything back together works just fine. set it at 80 PSI, and get 10 gpm flow rate Look up the regulator diagram on the watts web site. the only specialty tool was a 1 1/8" socket to remove the valve core.