*Estimates  are based on averages from a variety of information published on websites. Some water heater manufacturer websites also provide calculators based on the duration for the use case and other factors.

Contractors usually follow a guideline of around 20 square feet (2 square meters) of collector area for each of the first two family members. For every additional person, add 8 square feet (0.7 square meters) if you live in the U.S. Sun Belt area or 12–14 square feet if you live in the northern United States.

Most demand water heaters are rated for a variety of inlet temperatures. Typically, a 70ºF (39ºC) water temperature rise is possible at a flow rate of 5 gallons per minute through gas-fired demand water heaters and 2 gallons per minute through electric ones. Faster flow rates or cooler inlet temperatures can sometimes reduce the water temperature at the most distant faucet.

Image

For active systems, the size of the solar storage tank increases with the size of the collector -- typically 1.5 gallons per square foot of collector. This helps prevent the system from overheating when the demand for hot water is low. In very warm, sunny climates, some experts suggest that the ratio should be increased to as much as 2 gallons of storage to 1 square foot of collector area.

While generating electricity, Kaleidos also can provide 1.9 MW of thermal power for facility heating or water desalination

Sizing your solar water heating system basically involves determining the total collector area and the storage volume you'll need to meet 90%–100% of your household's hot water needs during the summer. Solar system contractors use worksheets and computer programs to help determine system requirements and collector sizing.

A properly sized water heater will meet your household's hot water needs while operating more efficiently. Therefore, before purchasing a water heater, make sure it's the correct size.

Replacing diesel generators in remote villages and providing resilient backup power for hospitals, datacenters, and military installations

Image

The worksheet example shows a total peak hour demand of 66 gallons. Therefore, this household would need a water heater model with a first hour rating of 66 gallons or more.

If you haven't yet considered what type of water heater might be best for your home, learn more about selecting a new water heater.

Tankless or demand-type water heaters are rated by the maximum temperature rise possible at a given flow rate. Therefore, to size a demand water heater, you need to determine the flow rate and the temperature rise you'll need for its application (whole house or a remote application, such as just a bathroom) in your home.

Additional calculations involved in sizing your solar water heating system include evaluating your building site's solar resource and determining the proper orientation and tilt of the solar collector. Visit the solar water heaters page for more on these calculations.

Hundreds of units can autonomously operate with data streaming back to Radiant’s centralized 24/7 fleet monitoring system tracking the health of each reactor

Meltdown-proof TRISO fuel, ceramic coated uranium particles, have been used in more than 30 grid-scale reactors since the 1960s

To properly size a storage water heater for your home -- including a heat pump water heater with a tank -- use the water heater's first hour rating. The first hour rating is the number of gallons of hot water the heater can supply per hour (starting with a tank full of hot water). It depends on the tank capacity, source of heat (burner or element), and the size of the burner or element.

Some types of tankless water heaters are thermostatically controlled; they can vary their output temperature according to the water flow rate and inlet temperature.

A small (50- to 60-gallon) storage tank is usually sufficient for one to two three people. A medium (80-gallon) storage tank works well for three to four people. A large tank is appropriate for four to six people.

The EnergyGuide label lists the first hour rating in the top left corner as "Capacity (first hour rating)." The Federal Trade Commission requires an EnergyGuide label on all new conventional storage water heaters but not on heat pump water heaters. Product literature from a manufacturer may also provide the first hour rating. Look for water heater models with a first hour rating that at least matches within your peak hour demand (the highest energy use during a single 1-hour period for your home).

Image

Subscribe to receive updates from Energy Saver, including updated content and energy saving tips for consumers and homeowners.

For sizing combination water and space heating systems -- including some heat pump systems, and tankless coil and indirect water heaters -- consult a qualified contractor.