Series LFMMV thermostatic mixing valves maintain and limit mixed hot water to a desired, selectable temperature. The LFMMV series can be set to any temperature between 80 deg F and 120 deg F with flow rates as low as 0.5 gpm and as high as 12 gpm the LFMMVs feature lead free* construction to comply with lead Free* installation requirements. The LFMMV-M1 uses a double throttling design to control both the hot and cold water supply to the mixed outlet. The superior flow characteristics of this valve provide accurate temperature control (±3 deg F) with low pressure drop across the rated flow range. As an added feature, the LFMMV-M1 series incorporates integral inlet filter washers and check valves in both the hot and cold water inlets to protect against clead free.

Inspection and testing activities differ for non-mechanical and mechanical backflow preventers. The following describes the type of inspection and testing that should be done for each of them.

Image

Federal, provincial, or municipal plumbing codes require backflow prevention for potable water systems. A well designed and properly maintained air gap at the supply fixture is the best means available for protection against backflow. However, an air gap is not always practical and is vulnerable to bypass arrangements that can nullify its effectiveness. If you do not use an air gap at the supply fixture to protect against backflow, a mechanical backflow preventer will serve the same purpose.

Image

You may use other guidance developed by provincial governments, industry associations, international partners or academic bodies as long as they can achieve the outcomes identified in the regulations. Always ensure that the guidance you choose is relevant for your particular business, product or products, and market requirements.

If your facility has a secondary or alternative water system, such as a sprinkler system, there is a risk of forming back pressure if the two systems are interconnected. Backflow is most likely to occur when the following conditions exist:

Methods used to prevent backflow may be simple or complex depending on the nature of the food processing environment. You may choose to have a qualified party assess your facility's backflow prevention needs and maintenance.

This document does not replace provincial or municipal plumbing codes. Regulated parties are responsible for ensuring that existing and new installations made in their facility meet applicable plumbing codes and regulations whether federal, provincial or municipal.

You can use several types of devices to prevent backflow as long as the device effectively prevents back-siphonage and can withstand backpressure if needed. A trained professional can help you choose the device that best fits your facility and system design.

The Canadian Food Inspection Agency (CFIA) created this document as guidance to help food businesses comply with the requirements set out in the Safe Food for Canadians Regulations.

The following references contain information that helps explain food safety controls, demonstrates how to develop them, and provides examples. The CFIA is not responsible for the content of documents that are created by other government agencies or international sources.

The CFIA verifies the compliance of a food business by conducting activities that include inspection, and surveillance. When non-compliance is identified, the CFIA takes appropriate compliance and enforcement actions.

While the document provides examples of measures to prevent backflow, it is not exhaustive ­the preventive measures needed will depend on the size and complexity of the food business and be unique for each business. The document does not cover:

Backflow of water presents a risk of contamination to the water supply and the distribution lines in an establishment. The use of prevention devices at key locations can help you prevent backflow and the contamination of the water supply.

Food businesses are responsible for complying with the law. They demonstrate compliance by ensuring that the commodities and processes for which they are responsible meet regulatory requirements. If a written preventive control plan (PCP) is required, the food business develops a PCP with supporting documents, monitors and maintains evidence of its implementation, and verifies that all control measures are effective.

Watts® LFMMV Thermostatic Mixing Valve, 1/2 Inch, Union x Solder, 9 gpm Flow Rate, Cast Copper Silicone Alloy, 4-13/16 Inch Length x 5-3/8 Inch Width

Image

Note: The CFIA recommends that a qualified person test backflow preventers. Provincial water and wastewater associations or municipalities may provide lists of certified or licensed testers.