Watervalve

Unlike standard carbon water filtration, the ultra-fine 0.0001-micron EcoHero-50 membrane removes a minimum of 90.8% of total dissolved solids (TDS) from water. This reverse osmosis system significantly reduces organic and inorganic compounds such as fluoride, viruses, bacteria, herbicides, pesticides, nitrates, algae, phosphates and more. The end result is great tasting, healthier, purified drinking water, in your own home or wherever you take your portable 4 stage reverse osmosis system with Remineraliser.

Regulating valve

*Cartridges may be subject to replacement earlier than the recommended period. This is dependant on individual usage and varying Australian water quality.

Piping Components – A Strainer is required upstream of the PRVs to keep them clear of trash. Pressure gauges are required on both the high-pressure and low-pressure sides of the PRVs to see what the pressure drop across the valve is.  Isolation valves on all PRVs and relief valves are required for maintenance.

More than just great-tasting and healthier for you, water produced from this system is great for washing fruit and vegetables, cooking with, tea and coffee, pets’ water dishes, watering plants and more!

PRV valve

Pressure Reducing Valves – stations are designed with a High-Flow and Low-Flow PRV that work in parallel to maintain a constant pressure downstream across the flow load profile of the zone. Low-Flow valves are typically direct-acting (ex. Cla-Val Model CRD-L), and High-Flow valves are pilot-operated (ex. Cla-Val Model 90-01); however actual valve selections depend on the flow and pressure drop of each station.

* EcoHero membrane test results provide a 50% recovery rate. Recovery rates will vary depending on inlet / holding tank pressure, water quality and the condition of the filters.

*Test results based on tests conducted 27/8/2018 on a 4 Stage Reverse Osmosis System and a 4 Stage Reverse Osmosis System with Remineraliser cartridge at SAFE Analytical Laboratories QLD.

While reverse osmosis is excellent for removing contaminants (such as heavy metals like cadmium, arsenic and chromium), healthy minerals and salts can also be removed leaving your water acidic. As part of this 4 Stage Reverse Osmosis System, the Remineraliser cartridge actually adds healthy minerals back into your water after the intense purification process.

Adding minerals back into your purified water via the Remineraliser cartridge, raises your water’s pH balance to a level considered alkaline. Minerals like calcium, magnesium, potassium and sodium are added for great potential health benefits such as improved gut and kidney health. Calcium, magnesium, potassium and sodium are all minerals that humans need for healthy teeth, bones and overall wellbeing.

Water pressureregulator

Better for the environment (and your home’s water usage), this system is fitted with the Pure Water Systems EcoHero-50 membrane. The EcoHero-50 is the latest in membrane technology, providing up to 300% improved wastewater efficiency when compared to rival membranes.

Relief Valve – Relief valves are required downstream of the PRVs to prevent over-pressurization when the PRV fails. A pilot-operated valve can be used (ex. Cla-Val Model 50-01), but we recommend a direct-acting valve like the Cla-Val Model 55B.

Of all methods to purify water, the process of reverse osmosis is one of the most effective and advanced. More than standard water filtration, the intense water purification process of reverse osmosis removes almost all contaminants found in drinking water, including total dissolved solids (TDS).

Pressure Reducing Valve (PRV) Stations are an essential component of a water-distribution system in a commercial building. The 2015 Uniform Plumbing Code Section 608.2 states that PRVs are required at any point where the system static pressure exceeds 80 PSI. Typically, this applies to mid- and high-rise buildings when the pressure boost to serve the upper floors is over 80 PSI. It takes a combination of valves and safety devices to create a Pressure Reducing Station.

Block Valve and Control Panel – The addition of a pressure switch, control panel, and block valve can add additional safety and monitoring to the PRV Station. When a PRV fails, the pressure switch detects the high pressure and sends a signal to the control panel. This triggers the panel alarms (local and BAS output) and closes the block valve to shut down the water supply to the zone.

Pressureregulator

Pressure ReducingValve

Enjoy purified drinking water of the highest quality with the EcoHero 4 Stage Reverse Osmosis with Remineraliser – Portable system.

This system includes a handy 15L bottle and tap adaptor to simply DIY install (no plumbing required), making it a perfect solution for people who are renting or on the move. It can be conveniently wall-mounted or placed on a bench for easy access to great tasting, healthy, purified drinking water.

So do we! Join our community to keep up with great new products, deals, exclusive offers and more, delivered to your inbox.

The EcoHero 4 Stage Reverse Osmosis with Remineraliser – Portable system is Watermark Certified and has NSF 42 Certified components. This system comes ready to DIY install, complete with cartridges and high-quality housing parts and fittings.