Next, downstream gas moves through the sense line protector. This device protects the pilot from over pressurization. It blocks the downstream pressure when it exceeds the adjustable limit and reopens when inlet pressure drops below the limit.

As this cycle repeats, liquids continue to fall out of the supply gas into the drip pot where it will need to be drained regularly, depending on the conditions.

Image

Now, supply pressure is blocked from going into the control valve actuator, and instead the diaphragm pressure is rerouted out through the pilot and vented.

This supply pressure pushes up on the control valve diaphragm working against the tension of the spring. This opens the valve and allows upstream pressure to move downstream.

Since delivering our first thermostatic mixing valve over 100 years ago, we have focused exclusively on designing and manufacturing the highest quality water temperature control valves in America. At Leonard Valve Company, craftsmanship isn't a lost art – it's something we do every day.

The rapid but stable repositioning of the pilot plug produces a throttling action, and the valve will open and closed by only a small percentage to maintain the set point.

Building Quality Mixing Valves is what we do at Leonard. At the same time we offer the industries best Service. It starts with the Best Engineers, followed by the most technically knowledgeable Regional Sales Managers, topped off with the industries best Specification Reps.  Our team of experts are easily accessible and have decades of market experience and knowledge on Mixing Valves and Mixing Valve Systems.

As this cycle repeats, liquids continue to fall out of the supply gas into the drip pot where it will need to be drained regularly, depending on the conditions.

When the adjustment screw is unthreaded, there is no downward pressure on the pilot diaphragm assembly. Once the adjusting screw is threaded farther into the bonnet, the spring puts pressure on the assembly, which positions the pilot plug to open the flow of supply pressure into the control valve actuator.

Image

In this example, the downstream pressure will hover around 99 PSI, where the valve is barely open, to 100 PSI, when the valve is closed.

Upstream pressure flows into the Drip Pot which knocks out liquid from the supply gas which could be detrimental to other instruments.

The supply gas regulator reduces the upstream pressure to 30 PSI;to provide supply pressure to the pilot after passing through a filter.

Once pressure has vented, and there is no longer enough pressure to overcome the pilot spring, the pilot diaphragm assembly will move back down.

In this video, we’re going to look at the production flow through this Pressure Reducing High Pressure Control Valve Package configured with a Diaphragm-Controlled High Pressure Pilot.

Beginning with the control valve in a closed position and the adjusting screw not yet calibrated to a desired set point, the upstream pressure begins to flow – in this example, up to a pressure of 400 PSI.

Our expert team of sales engineers can help you with all stages of your project — valve design & selection, plumbing & building code and specification assistance.  Some of our professional installs are shown here.

Every building is different and all manufacturers of mixing valves pipe recirculation uniquely. We have a video to help explain the basic design of a tempered recirculation system with a Master Mixer. This video will help the plumbing professional select the proper piping method for the job.

For reducing pressure in high pressure application, you can use a High Pressure Control Valve package set up for pressure reducing application.

Each monthly newsletter includes information on product improvements, tips on how to better optimize your site, videos and articles on how to complete your own repairs, as well as news about training and events.

Image

Our Production Team is committed to manufacturing the finest water temperature control valves in the industry. Today we supply high/low master mixers, complete water tempering systems, emergency mixing valves, and shower valves, along with a myriad of other valve products to meet the stringent demands of today's commercial buildings.

Next, downstream gas moves through the sense line protector. This device blocks pressure to the pilot when it exceeds the working pressure of that pilot.

As the sense pressure approaches the set point, it causes the bellows to contract, actuating the bellows stem to move it upward against the diaphragm assembly.

In this video, we’re going to look at the production flow through this pressure reducing control valve package, configured with a Bellows Controlled High Pressure Pilot.

When the adjustment screw is unthreaded, there is no downward pressure on the pilot diaphragm assembly. Once the adjusting screw is threaded, the spring puts pressure on the assembly which positions the pilot plug to open the flow of supply pressure into the control valve actuator.

American Society of Sanitary Engineers publishes product standards of safety for plumbing systems.  There are 5 major standards for mixing hot and cold water.  Four of these standards are mentioned specifically in both the IPC and UPC Plumbing codes as well as the four states that use their own codes (California, Illinois, Wisconsin, and New Jersey).  Commercial building require ASSE certified valves. Click below to understand how and when to use these valves. As always, you may contact a Leonard Sales/Engineering Specialist for assistance.