Dielectric UnionGasket

System should be installed indoors on hot water service systems. The timer control is designed to turn the circulator on and off at pre- set times, allowing the ...

Series 994 Reduced Pressure Zone Assemblies SIZE RANGE: 2½" through 10". Series 994 Reduced Pressure Zone Assemblies are designed to provide protection of the potable water supply in accordance with national codes. This series can be used where approved by the local authority having jurisdiction on health hazard cross-connections. Series 994 features a short lay length, lightweight stainless steel body, corrosion resistant stainless steel relief valve, and patented torsion spring check valves. Pressure / Temperature Temperature Range: 33°F – 110°F (5°C – 43°C) continuous Maximum Working Pressure: 175psi (12.06 bars) 994 Data Sheet (pdf)

HARTdielectric Union

Series 994HMB Portable Hydrant Meter backflow Preventers SIZE RANGE: 2½' to 7NST x 3". Model 994HMB Portable Hydrant Meter Backflow Preventers prevent the reverse flow of polluted water from entering into the potable water supply where flow is in one direction and the possibility of cross-connections exists, such as at a fire hydrant or other non-permanent installation. It consists of a stainless steel body construction with stainless steel internal parts, meter housing, measuring element, and permanently sealed register to measure flow and protect the meter and backflow preventer from damage due to excessive flow. Series 994HMB meets AWWA C701 meter requirements and is ideal for use in existing hydrant meter hookups. Factory assembled and tested.

Series 957 Reduced Pressure Zone Assemblies SIZE RANGE: 2½" through 10". Watts SilverEagle Series are the lightest and most compact backflow prevention assemblies in the industry. Series 957/957N/957Z Reduced Pressure Zone Assemblies provide protection to the potable water system from contamination in accordance with national plumbing codes. Series 957/957N/957Z are normally used in health hazard applications for protection against backsiphonage or backpressure.

dielectric union2"

Pressure / Temperature Temperature Range: 33°F – 140°F (5°C – 60°C) Maximum Working Pressure: 175psi (12.06 bars)

Watts® LF009 Series Backflow Preventer is engineered to stop contaminated water from flowing back into the clean water supply due to backsiphonage or back ...

Dielectric Unionfor electrical conduit

Dielectric unionwater heater

Series 009 Reduced Pressure Zone Assemblies SIZE RANGE: 1/2" through 3".Series 009 Reduced Pressure Zone Assemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series features two in-line, independent check valves, captured springs and replaceable check seats with an intermediate relief valve. Its compact modular design facilitates easy maintenance and assembly access. Sizes 1⁄4" – 1" (8 – 25mm) shutoffs have tee handles. Pressure / Temperature Series 009 1⁄4" – 2" (8 – 50mm) is suitable for supply pressure up to 175psi (12 bars). Water temperature: 33°F – 180°F (-3°C – 75°C). Sizes 21⁄2" and 3" (65 and 80mm) are suitable for supply pressures up to 175psi (12 bars) and water temperature at 110°F (43°C) continuous, 140°F (60°C) intermittent. 009 Data Sheet (pdf), 919 Data Sheet (pdf),

Industries at a Glance: Industry at a Glance Home.

Dielectric unionpurpose

Series 995 Reduced Pressure Zone Assemblies SIZE RANGE: 1/2" through 1½". Series 995 Copper Body Reduced Pressure Zone Assemblies are designed to protect the potable water supply in accordance with national plumbing codes and water authority requirements. Series 995 features two in-line, independently operating modular check valves, a bottom mounted hydraulically operated differential relief valve, two ball valve shutoff valves, four test cocks, and is serviceable without the use of special tools. Pressure / Temperature Temperature Range: 33°F – 180°F (5°C – 75°C) continuous Maximum Working Pressure: 175psi (12.06 bars) 995 Data Sheet (pdf)

Browse our line of sturdy gate valves for reliable water flow control. Our valves offer easy operation and leak-free performance. Shop now!

Series 909QT Reduced Pressure Zone Assemblies SIZE RANGE: 3/4" through 2". Series 909 Reduced Pressure Zone Assemblies are designed to provide superior cross-connection control protection of the potable water supply in accordance with national plumbing codes and containment control for water authority requirements.With its exclusive, design incorporating the patented "air-in/water-out" principle it provides maximum relief valve discharge during the emergency conditions of combined backsiphonage and backpressure with both checks fouled. Model 909-QT, standardly furnished with full port, resilient seated and bronze ball valve shutoffs. Sizes 3/4" and 1" (20, 25mm) shutoffs have T handles.. Series 909 Reduced Pressure Zone Assemblies SIZE RANGE: 2½" through 10". Series 909 Reduced Pressure Zone Assemblies are designed to provide crossconnection control protection of the potable water supply in accordance with national plumbing codes. With its exclusive patented relief valve design incorporating the “air-in/water-out” principle, it provides substantially improved relief valve discharge performance during the emergency conditions of combined backsiphonage and backpressure with both checks fouled. Pressure / Temperature Temperature Range: 33°F – 180°F (5°C – 75°C) continuous, Maximum Working Pressure: 175psi (12.06 bars) 909QT Data Sheet (pdf) -909 Data Sheet (pdf)

Stainless Steeldielectric union

dielectric union1"

18 Oct 2019 — ... Febco Sales, Inc. c. Watts. d. Zurn/Wilkins. 10. Double Check ... seated valves. G. Renewable Seats: Select and install valves with ...

202178 — ... GROVEPORT, OH, 43125, USA. US · Ohio · Groveport · 6201, Green Pointe Drive South; Watts Water Technologies - Groveport, 6201 Green Pointe Drive ...

This Site The Web All Major Credit Cards Accepted E-mail: nni_inc@hotmail.com Phone: 305-687-3330

Goulds Circulate hot water in your home. Reduces wait time for hot water and conserves water.

Interact with customers to provide basic or scripted information in response to routine inquiries about products and services. May handle and resolve general ...

Publication 8 (PUB 8), Construction Manual, updates the previous version of PUB 8, dated 2008. The Construction Manual is to be used as a guide and a ...