TacoAir Separator

Provide complete with internal baffle, inlet, outlet, baffle fitting and vent openings. ... Flanged ends with resilient seated wedge, ductile iron ... 4) Febco.

... Tekmar Hydronic Control Systems - Image 1. Tekmar Hydronic Control Systems. Request a Quote Product Support. Product Features. Setpoint Controls. Boiler Reset / ...

6Air Separator

A. Flow from four or fewer kitchen fixtures enters the grease trap. B. An approved flow control or restricting device is installed to restrict the flow to ...

Air separatorin HVAC

Air separator tanks are used to remove entrained air within liquid systems, applicable to both open and closed loop heating systems.  It is important to remove entrapped air because it reduces the heat system efficiency and precise control of temperature. Systems using air separators often require less chemicals for pH and corrosion control  because dissolved oxygen, carbon dioxide and other non-condensable gasses are removed from the condensate on its way to the feed tank.  To remove the entrained air, the condensate enters the separation tank tangentially to the vessel body, creating a centrifugal vortex downwards towards the lower tangentially mounted outlet nozzle (the tangential nozzle orientation accomplishes air separation with the minimal tank body size possible). The resulting low velocity centrifugal force propels the heavier "air free" condensate towards the outer edges, releasing the entrained air into the center of the swirling vortex where it can rise upwards through the vessel vent port and float style air vent.  Sediment collects within the lower dished head section and can be periodically blown-down from the system as required. Our standard air separator tanks are constructed of carbon steel and both designed and manufactured in accordance with the latest edition of ASME Code Section VIII Div. I, including code stamp.  Tanks 3" and larger are offered with 150# ANSI flanged nozzles, although as a custom fabricated vessel we can accommodate whatever type of connection is most compatible with your design.  We have constructed air separation tanks from stainless steel and for working pressures up to 3,000 PSIG.How to Size Air Separator Vessels Each air separator vessel size has an associated maximum capacity rating and a Cv rating (used to calculate pressure drop across the vessel). Step 1: Select an air separator vessel size having a maximum capacity larger than the maximum flow rate for your application.  Since these are custom fabricated pressure vessels, we can reduce the inlet/outlet connection size to match your pipeline, so base sizing on the smallest vessel size which satisfies your intended flow rate.

You can also work the formulas backwards, determine the desired efficiency, find the corresponding % of maximum capacity value and divide your flow rate by that percentage: (350 GPM/0.1842) = 1,900 GPM, so you would be looking for an air separator size that has a maximum capacity of at least 1,900 GPM.  Once again, if the "vessel size" is larger than your inlet/outlet piping, we can simply reduce the connection sizes to match your piping.

Image

Step 2: Divide your maximum flow rate by the maximum capacity to obtain the percentage of the total capacity used.  For example, lets say that your application uses 350 GPM and you are looking to maximize air separation, choosing an 8" size vessel (having a maximum capacity of 1,900 GPM; this equates to using about 18.42% of the total capacity available.Step 3: Draw a vertical line from the capacity used (18.42%) and where it intersects with the efficiency curve is the approximate air removal efficiency; continuing with our example, an 8" size air separator vessel would eliminate approximately 98.5% of entrained air with each pass through the unit.  In a closed loop system, such as a boiler system, it might require several passes to remove most of the air from your system and thereafter only air attributed to make-up water will need to be removed.

CaleffiAir separatorrebuild Kit

AEM WATER/METHANOL INJECTION 200PSI RECIRCULATION PUMP W/3/8" NPT FITTINGS - AEM.

Air separatorhow it works

FIG SERIES 209MXL Dielectric Union Lead-Free, Male Iron Pipe x Brass Sweat. Male Iron Pipe x Brass Sweat. Dielectric Union 209 MXL.

Mixing valves are devices that blend multiple streams of fluid at varying temperatures to produce a desired output temperature. Hot and cold water mixing ...

Air separatorvalve

2023328 — A backflow preventer stops contaminated water from flowing back into the public water supply. Without it, pollutants can enter the water supply and compromise ...

The SharkBite washing machine angle valve features a quarter-turn angle stop valve and is ideal for use in washing machine installations. View now.

Image

LF25AUB-Z3 - 1/2" ... Description: This lead free water pressure reducing valve is designed to reduce incoming water pressure to protect plumbing systems and ...

The Cash Acme Washing Machine Shut-Off Valve is a Single-lever control of both hot and cold water to protect a washing machine's hose and inner working ...