Some reasons for installing a pressure reducing valve in a property include – lowering the pressure and therefore strain on your pipework and appliances, sometimes to conserve water, to stop all reduce water hammer problems (knocking on paperwork) or just because people prefer to have lower pressure in their property.

Watts LF7C

WATTS® Dual Check Valve, Series: LF7RU2-2, 3/4 in Nominal, FNPT, 175 psi, 33 to 180 deg F, Low Lead Compliance: Yes, Media: Water, 3-5/8 in Inlet to Outlet Length, Copper Silicon Alloy Body, Stainless Steel Spring/Santoprene Disc Trim, EPDM Seal, 1-7/8 in H, Domestic

Image

Although this it is not an especially uncommon occurrence, doing it regularly suggests a problem with the central heating system, which could be associated with a water leak. As we have discussed before this can be caused by a number of factors one of which is possibly a problem with the pressure relief valve itself.

A tundish is a funnel shaped, often plastic, connection with a feed (usually from your PRV on your pressurised boiler) with a collection cup at the bottom feeding to a drain. There is a visible air gap between the top and bottom on a tundish to allow you to see any PRV boiler leaks and also to stop any water (from the drain) going back into the boiler system, which could cause issues. If you see your tundish leaking, you could have a problem.

Watts Dual Check Valve 1 inch

Image

Just to confuse matters more, some people refer to them as Safety Relief Valves (SRVs) or even Safety Release Valves! Remember also that these terms are used for applications other than central heating boilers, for example on an air compressor or even industrial machinery. More on that later.

In some respects a pressure release valve explains itself what it does but let’s help with a simple explanation, other than ‘a device to relieve pressure’.

Image

If you have need help finding a water leak at your home with our trace and access service, get in touch with our friendly team today. We offer these services to both domestic and commercial customers, including commercial leak detection.

Pressure relief valves are clearly there to serve a purpose and function for your central heating system and it wouldn’t be considered very unusual for them to be triggered from time to time in small amounts.

WATTS® 0072204 LF7RU2-2 Dual Check Valve, 3/4 in Nominal, FNPT End Style, Low Lead Compliance: Yes, Copper Silicon Alloy Body, Domestic

Basically, if the pressure on the system reaches the calibrated level it releases some water out of the system to reduce the pressure then sealing again once the pressure has reduced to normal levels. Notice how, given their importance as a safety feature that the have a CE Marking (CE1115).

As we said previously, each pressure relief valve is calibrated to a specific pressure and the key component of this is the calibrated spring within the body of the PRV.

WattsLF7RDual Check Valve

As we said earlier pressure relief valves or safety relief valves can be found in other applications not just on boilers and heating systems. They can be used in devices and machinery where water, air, oil and gas are used. In general they are for safety purposes and to protect the machinery or devices themselves. This is a bit like isolation valves, which have a number of applications.

Series LF7R Lead Free* Dual Check Valves prevent the reverse flow of polluted water from entering into the drinking water supply at the service entrance or at individual outlets. It consists of a Lead Free* cast copper silicon alloy body construction, with two compact replaceable plastic check modules, and stainless steel springs. Series LF7R is designed for non-health hazard residential water system containment, continuous pressure applications. It is installed immediately downstream of the residential water meter, in a vertical or horizontal position. Check with local inspection authorities for installation requirements. Minimum Working Pressure: 10psi (69 kpa) Maximum Working Pressure: 175psi (12 bar).

We have an interesting report on experimenting with a water testing kit, which you’ll find useful, and very much linked to this article a great guide to Central Heating Leak Detection.

Pressure relief valves especially come into the equation when someone has a boiler pressure dropping causing it to turn off and central heating not to work. In such situations people sometimes find themselves needing to top up their boiler pressure in order to get it working again.

PRV faults can be caused by a number of reasons, including wear and tear, decay corrosion or a compromised seal. If the PRV is faulty, then it will possibly be releasing water from the system when it shouldn’t be either because the mechanism is not releasing at the correct pressure (normally lower) all the seat is not making a watertight seal.

However, if you are seeing a lot of water being released, it is happening regularly or even constantly you likely have a fault that needs to be investigated. Otherwise, as we said above it will compromise the functioning of your central heating boiler system, this may show as an F1 boiler error or Vaillant F75 boiler error, also E119 boiler error and F22 Boiler errors.

Pressure relief valves are effectively a safety mechanism for the boiler and central heating system To relieve pressure on the system when it gets too high. as you can see from the image below, pressure relief valves are set at a specific pressure level, often 3 bar, like this one below:

watts dual check valve 3/4

With Pressure Relief Valves, some people call them pressure release valves, some even call them PRV valves (the ‘V’ obviously stands for valve already) but effectively they are talking about the same thing usually when it comes to boilers leaking a subset of which is combi boilers leaking if a pressure relief valve leaking on a combi boiler in particular.

Pressure relief valves can be found number of areas but generally they are located in close proximity to the boiler on the connections between the pressurised central heating boiler itself. Remember that a non-pressurised or vented system will unlikely have one at all. They are often vented to a tank in the loft (or elsewhere) when there is expansion.

if a pressure relief valve fails then not only will it potentially stop your central heating system boiler from working effectively or at all, plus it can mean that water is expelled from your central heating system, leaking out of the outlet pipe which is often found on the wall outside the boiler.

Like pressure relief valves, expansion tanks can fail too, especially if the water and air tight seal between the air and water areas of the tank is broken. If that happens on a expansion vessel then water will enter the area for air and can cause the boiler pressure to drop, sometimes enough to stop the boiler working.

Along the way to drain outside, often close to the boiler will be a tundish drain which is a funnel shaped (often plastic), drain with an air gap. This air gap serves two purposes. Firstly it allows you to see if water is leaking from your PRV through the tundish. Secondly, the air gap prevents any, potentially contaminated water from drains etc being drawn back in to the boiler, which could cause damage.

watts lf7ru2-2

Expansion vessels working conjunction / compliment pressure relief valves, in particular in handling smaller variances in water pressure / expansion and contraction. Expansion vessels can be integral or exterior to the boiler itself. There are different designs, shapes colours, etc.

As we said earlier small day to day variances in the pressure within your central heating system are not particularly unusual and help control that, in particular when warm water causes expansion in the system (also increasing pressure), expansion vessels are there to help manage this.

WattsLF7Rpdf

To find out more about a similar subject, see our water pressure calculator and likewise with our Boiler Pressure Low? – Leak Calculator. We also have a really useful article about some considerations regarding heating pipe leak sealer including pros and cons.

As a result of this, water will be being released from the pressurised system dropping the boiler system pressure which over time may cause it to stop working and require being repressurised.

pressure relief valve can fail for a number of reasons including general wear and tear, broken seals, broken or damaged springs and also because debris has got into the mechanism compromising its effectiveness. most of these problems are resolved by either repairing or replacing the PRV.

That said pressurised or sealed central heating systems should have a pressure relief valve. as we explained in our article about boilers losing pressure, pressurised boiler systems have an optimal range of pressure they operate in. The actual operating pressure of the boiler will vary from time to time including when it is on versus when it is off on many occasions

They will often look something like the diagram above. So as the water pressure rises slightly the diaphragm, often made of rubber material, will stretch compressing the air above and then when the pressure falls the reverse happens.

the outlets for the PRV, in other words where the outflow water goes to, commonly feed to the exterior of the property like the example shown below so that any excess water drains outside.

Watts Dual Check Valve

In many situations the pressure relief valve itself is attached in and around the pipework close to the boiler, and although there are many different designs, commonly they look like the pictures shown in this article. They are usually accessible so that boiler engineers etc can’t access them to inspect, repair or replace them.

As the pressure from the inflow increases and reaches a certain level the PRV seat seal pushes up on the stem / spindle against the resistance of the PRV spring releasing the flow of water by the outflow once the pressure has lowered to accept levels the seal is closed and water stops flowing out.

It is quickly worth mentioning as usual that exactly how boilers and central heating systems are set up will vary according to the type of boiler and how is being installed.

When carrying out water leak detection work something which frequently comes into consideration is understanding Pressure Relief Valves (PRVs) on boilers, Which are not to be confused with pressure reducing valves (also called PRVs in the plumbing world!), which we will explain further later.

If a pressure relief valve has been triggered and released water that can in some instances be a trigger for debris to get into the mechanism / seal causing future issues, so be aware of this.

wattslf7r1/2

To help explain how a pressure relief valve works we have put together this basic diagram above showing the main component parts and how it works. This includes:

We thought it was worth adding a section about pressure reducing valves which are not the same as pressure relief valves. pressure reducing valves are commonly used in domestic and commercial properties to reduce water pressure into the building all part of the building this can be for a number of different reasons.

If water continues to flow out even the pressure is within acceptable levels then there is a possibility of a fault with the PRV which we will look into now in more detail.