All of our RO/RODI Systems are made with the highest quality parts, handpicked by our Owner and Lead Engineer, Charles Mitsis; built by hand and tested right ...

Let's answer with an example application. A large industrial manufacturing plant may have four separate cleaning areas throughout their facility that require 120°F water to wash off products between production steps. A central hot water system is installed to supply hot water to these areas. The system itself has to operate at 140°F (for reasons we'll explain below), so thermostatic mixing valves are installed at each cleaning room to blend 140°F hot water and 60°F cold water together to create the 120°F tempered water desired. With this example in mind, now to explain the challenges being addressed by setting the central hot water system at a higher temperature than the end-use temperature:

4. Isolate from Other Thermal Sources - mixing valves rely on their internal or external thermostat to properly achieve the desired outlet temperature, but if the thermostat is being influenced by adjacent hot or cold thermal sources, the valve could miss its target.

Thermostatic mixing valvehow it works

• National and State Building Codes - nationally-recognized building codes such as the Uniform Building Code (UBC) and International Building Code (IBC) are adopted and enforced by states that don't otherwise publish their own state building code.

BRASS BOILER DRAIN MIP 3/4 NL. Image. HBD75NL. BRASS BOILER DRAIN MIP 3/4 NL. Supporting Info. Click to Download PDF Catalog (Opens in New Tab).

202246 — Gate valves are generally bad choices for regulating flow or operating in any orientation other than fully open or fully closed.

Thermostatic Mixing ValveBath

DESCRIPTION. Series 7 dual check valves prevent the reverse flow of polluted water from entering into the drinking water supply at the service entrance or at ...

• OSHA - federal and state-level Occupational Safety and Health Administration offices issue standards that often reference other regulations, integrating these requirements together for the specific purpose of protecting worker safety.

Hot water is a widely regulated utility, with many governing agencies having a say in the design and temperature setpoint of any given system regardless of the industry or application. Below are the most common regulatory bodies involved with water temperature, and readers are encouraged to confirm their applicable requirements with local building officials, licensed mechanical engineers, and/or licensed plumbing contractors.

Controls both hot and cold water simultaneously protecting machine parts and hoses from damaging effects of water pressure.

Thermostatic mixing valveoutside tap

Thermostatic Mixing Valve22mm

• ASSE - the American Society of Sanitary Engineers publishes standards aimed at preventing unsanitary design in plumbing systems. Most thermostatic mixing valves will be specified as compliant with an ASSE standard, as this is the most widely adopted spec by manufacturers and code inspectors.

• Industry Guidelines - a wealth of information specific to certain industries and applications can be found through industry trade associations, non-profits, national laboratories, and academic sources.

Zurn® Light Commercial® FD2375 Floor Sink, 12 in W x 12 in H, Cast Iron Compare Zurn® Zurn® Z1901-3NH Sani-Flor Receptor With Grate, Square, 12 in W x 10-5

Thermostatic mixing valves are mechanical devices that connect to hot and cold water sources, and by regulating the proportion of hot to cold water blended together within the valve, they automatically provide tempered discharge water at a specific temperature. Inside the valve, a spring-loaded thermostat dynamically adjusts the amount of hot and cold water flowing through the valve, with the spring tension set to achieve the desired outlet temperature (either adjusted by an operator or set constant at the factory).

Thermostatic Mixing Valve28mm

Thermostatic mixing valvetemperature setting

Commercial Filtration Supply (CFS) is a leading Authorized Filtration Distributor for Eaton, Titan, NeoLogic, Spears and other top brands. CFS proudly offers deep discount pricing and easy ordering for all your filtration needs. Learn More

• Local Municipal and Public Health Codes - local building departments are the most direct regulators of hot water temperatures in new and remodel construction projects. Local and regional public health departments are often the regulating bodies charged with ongoing enforcement where public health is involved, such as with food manufacturing and restaurants.

Thermostatic Mixing Valve15mm

Many commercial and industrial applications call for heated water at a temperature safe for human contact. Facilities often install high-temperature central hot water systems for a variety of technical reasons, and this high-temp water produced must be tempered down to safe levels before connecting to sinks, showers, hose stations, and manufacturing equipment. To perform this tempering work, we turn to thermostatic mixing valves, a class of valves that blend hot and cold water streams together on the fly to achieve a desired intermediate water temperature. In this article, we'll discuss the purpose and function of thermostatic mixing valves, including installation tips and regulatory considerations.

• National Industry Codes - certain nationally regulated industries will have their own requirements, such as the United States Department of Agriculture's standards for food manufacturing facilities.

WATTS LF009M2-QT-S Lead Free Cast Copper Silicon Alloy Backflow Preventer Reduced Pressure Zone Assembly With Strainer And Quarter-Turn Ball Valve, 2 IN, ...

1. OEM Requirements - follow the manufacturer's installation and maintenance requirements explicitly. Some details such as orientation and straight piping lengths can impact the valve's ability to reliably hit the desired outlet temperature, or worse, could risk dangerous failure. Even if two different models physically appear similar, check the manual - they may have important internal differences that impact installation.

• Thermal Losses - hot water will drop in temperature as it sits in storage tanks and flows through distribution piping, so is often generated at higher temperatures in order to tolerate shedding heat during transit but remain above the desired minimum end-use temperature.

Pressure Relief Valves is a safety device or alarm used to limit or control the pressure level in a system, within a safe threshold to avoid an overpressure ...

Different manufacturers will have different requirements for the installation of their thermostatic mixing valves, though there are a handful of universal best practices to keep in mind, including:

• Microorganism Defense - domestic water is highly susceptible to microorganism and bacterial activity (notably legionella), especially at warm temperatures which drive rapid spore propagation. Heating water above this spore growth temperature range can inhibit and destroy these microorganisms.

• Energy and Consumption Efficiency - compared to non-recirculated hot water lines from hot water heaters, thermostatic valves cut water waste and energy consumption by reducing the amount of time an operator has to draw water before it hits the desired temperature.

Flomatic Valves Pressure Reducing Valve, Bronze, 3/4", 15-150 PSI, C150100E These valves regulate high incoming line pressures to lower constant pressures ...

2. Hydraulic Design - thermostatic valves are not just selected for their pipe size, but also for specific hydraulic conditions such as pressure, flow, temperature, and fluid properties. For example, hydraulically undersized valves can cause pressure and flow issues, and oversized valves can lead to poor temperature regulation.

• ANSI - the American National Standards Institute is a nonprofit organization that publishes voluntary consensus standards that many code enforcers, manufacturers, installers, and end users choose to adopt.

Thermostatic Mixing Valvetap

• Regulatory Compliance - given the above point, substantial regulatory and legal requirements govern water temperature as a function of public health and employee safety.

3. Minimize Discharge Leg Distance - once tempered water is produced through the mixing valve, it must flow to the point of use through its discharge piping. If this discharge leg is too long, tempered water will take a relatively long time to push out the residual cold water in that leg and make it to the point of use. Especially for sinks and eyewash stations where immediate tempered flow is expected, mixing valves should be installed as close to the fixture’s inlet connection as possible.

To recap, hot water systems used in commercial and industrial applications often generate hot water at a higher temperature than needed for reasons rooted in energy efficiency, water-borne illness defense, and regulatory compliance. Large systems may produce over 140°F water in order to stave off legionella blooms, but this water must be stepped down to safer temperatures before the water is discharged for human contact (typically 80°F to 120°F). Other process applications will have different temperature profiles. Thermostatic mixing valves provide a simple mechanical solution for blending hot and cold water streams to create this tempered discharge. When installed correctly, in full compliance with applicable regulatory requirements, and properly maintained, thermostatic valves can operate behind the scenes providing safe, consistent, on-demand tempered water for the life of your commercial or industrial application.

Watts 957 2 1/2 inch stainless steel reduced pressure zone assembly backflow preventer helps prevent the reverse flow of contaminated water from being ...